Fuel & Lube Oil Kits & Reagents
Fuel & Lube Oil Condition Monitoring Test Kits
Find the solution that works for you.
Reagents:
Test Kits:
UniFuel & Lube Oil - Combined Easyshaker Test Kit Plus (Viscosity)
Recommended reagents / parameters:
Parameter
Base Number [BN,TBN]
Water-in-Oil [WiO in V%] Fresh/Used Oil comparator
Measurement Range
3 – 150 mgKOh/g
0 – 10 V% Liquid/paste
-
Type Of Reagent
Liquid
Liquid/Paste
-
Recommended reagents / parameters:
Parameter
Base Number [BN,TBN]
Water-in-Oil [WiO in V%]
Measurement Range
3 – 150 mgK Oh/g
0 – 10 V% Liquid/paste
Type Of Reagent
Liquid
Liquid/Paste
Malt / TTC Dipslide Tests for Yeasts, Moulds, Fungi and Total Viable Count in waters and surfaces.
A dipslide tests microbial content on liquids or surfaces using a sterile culture medium, incubated for 48 hours to estimate microbial colonies and assess treatment effectiveness. Liquid and surface testing.
Each Unimarine Dipslide pack contains 10 dipslides along with a comparison chart to obtain the test result.
Recommended reagents / parameters:
Parameter
Abrasive Iron
Measurement Range
0 – 19999 ppm
Type Of Reagent
Syringes/Caps
Recommended reagents / parameters:
Parameter
Compatibility and Stability
Measurement Range
-
Type Of Reagent
Filters/Syringes
Recommended reagents / parameters:
Parameter
Compatibility and Stability
Measurement Range
-
Type Of Reagent
Spot test paper
Recommended reagents / parameters:
Parameter
Base Number [BN,TBN]
Water-in-Oil [WiO in V%]
Measurement Range
3 – 150 mgK Oh/g
0 – 10 V% Liquid/paste
Type Of Reagent
Liquid
Liquid/Paste
RBS/TTC Dipslide Tests for Yeasts, Moulds, Fungi and Total Viable Count for food and manufacturing industry.
A dipslide tests microbial content using a sterile culture medium, incubated for 48 hours to assess treatment effectiveness based on colony counts. Liquid & Surface Testing. Flexible paddle for effective surface contact.
RBS/TTC Dipslide Tests for Yeasts, Moulds, Fungi and Total Viable Count for food and manufacturing industry.
A dipslide tests microbial content using a sterile culture medium, incubated for 48 hours to assess treatment effectiveness based on colony counts.
(with optional PrimeLab 2.0 Photometer)
Test kit for determining iron-in-oil concentration in lubricants. Measures total iron, not only corrosive iron. With magnet, abrasive iron can also be
measured separately.
Test kit can be combined with the Photometer and provide extra testing at the customer’s request.
Recommended reagents / parameters:
Parameter
Aluminium-in-Oil
Silica-in-Oil
Measurement Range
1 - 100 ppm
1 - 100 ppm
Type Of Reagent
Tablets
Powder
Recommended reagents / parameters:
Parameter
Base Number [BN,TBN]
Water-in-Oil [WiO in V%]
Fresh/Used Oil comparator
Salt-in-Water
Measurement Range
3 – 150 mgKOh/g
0 – 10 V%
-
Yes/No
Type Of Reagent
Liquid
Liquid/Paste
-
Liquid/Strips
Recommended reagents / parameters:
Parameter
Base Number [BN,TBN]
Water-in-Oil [WiO in V%]
Measurement Range
3 – 150 mgK Oh/g
0 – 10 V% Liquid/paste
Type Of Reagent
Liquid
Liquid/Paste
Recommended reagents / parameters:
Parameter
Base Number [BN,TBN]
Water-in-Oil [WiO in V%] Fresh/Used Oil comparator
Measurement Range
3 – 150 mgKOh/g
0 – 10 V% Liquid/paste
-
Type Of Reagent
Liquid
Liquid/Paste
-
Malt/TTC Dipslide Tests for Yeasts, Moulds, Fungi and Total Viable Count in waters and surfaces.
A dipslide tests microbial content on liquids or surfaces using a sterile culture medium, incubated for 48 hours to estimate microbial colonies and assess treatment effectiveness.
Recommended reagents / parameters:
Parameter
Abrasive Iron
Measurement Range
0 – 19999 ppm
Type Of Reagent
Syringes/Caps
Recommended reagents / parameters:
Parameter
Compatibility and Stability
Measurement Range
-
Type Of Reagent
Filters/Syringes
Recommended reagents / parameters:
Parameter
Base Number [BN,TBN]
Water-in-Oil [WiO in V%]
Fresh/Used Oil comparator
Salt-in-Water
Measurement Range
3 – 150 mgKOh/g
0 – 10 V%
-
Yes/No
Type Of Reagent
Liquid
Liquid/Paste
-
Liquid/Strips
*Manual available upon request
RBS/TTC Dipslide Tests for Yeasts, Moulds, Fungi and Total Viable Count for food and manufacturing industry.
A dipslide tests microbial content using a sterile culture medium, incubated for 48 hours to assess treatment effectiveness based on colony counts. Liquid & Surface Testing. Flexible paddle for effective surface contact.
RBS/TTC Dipslide Tests for Yeasts, Moulds, Fungi and Total Viable Count for food and manufacturing industry.
A dipslide tests microbial content using a sterile culture medium, incubated for 48 hours to assess treatment effectiveness based on colony counts.
Recommended reagents / parameters:
Parameter
Aluminium-in-Oil
Silica-in-Oil
Measurement Range
1 - 100 ppm
1 - 100 ppm
Type Of Reagent
Tablets
Powder
Recommended reagents / parameters:
Parameter
Sulphur in Fuel
Measurement Range
16 – 50000ppm
Type Of Reagent
Filters/Syringes/Caps
Recommended reagents / parameters:
Parameter
Compatibility and Stability
Measurement Range
-
Type Of Reagent
Spot test paper